| Sector | abcHealth Services/Equipments | Tender Value | INR 10 Crore | Location | Kerala - India | Ref.No | 45893163 | Closing Date | 27 - Oct - 2021 | | | Empanelment of suppliers for cardiothoracic surgery and cardiac anaesthesia items (including cardiac perfusion items) - surgeons suture needle 1/2, mini sucker, monopolar edge coated insulated blade electrodes, haemostatic natural bio polymer patch dressing for surgical bleeding control size 5 x 5 cm, human fibrin sealant free of aprotinin, 1 ml kit, human fibrin sealant free of aprotinin, 2 ml kit, minor fenistrated drape cvc drape, dvt standard calf (anti embolism stockings), dvt large calf (anti embolism stockings), dvt standard calf thigh (anti embolism stockings), dvt standard foot (anti embolism stockings), oral care suction tooth brush 25units/box), un sterile tubing roll 1/4 x 45 mtrs, vascular clip titanium large orange - (6 clips / catridge)-heart shaped wire, vascular clip applicator for small titanium clips., vascular clip applicator for medium titanium clips., vascular clip applicator for large titanium clips., vascular clip applicator for micro titanium clips., cautery tip cleaner, thoracic catheter size 24 angled (chest drainage catheter), thoracic catheter size 28 angled (chest drainage catheter), thoracic catheter size 32 angled (chest drainage catheter), thoracic catheter size 36 angled (chest drainage catheter), tourniquest, surgi i loop(maxi), surgi i loop(mini), aortic punch 2.5, aortic punch 3.5, aortic punch 5.0, instrument marker (all colors are available), bioglue 2 ml, bioglue 5 ml, bioglue 10 ml, surgical gown, pneumostat, suture organizer, tisseel kit vhsd a 2ml india, tisseel kit vhsd a 4ml india, floseal kit, hair clipper blade, opsite large, alcohol swab, chest drainage system adult 2000 ml (under water seal drainage system), asepto pump (for bladder flushing), small drape sheet (100 cm x 80 cm), drape sheet 160 cm x 80 cm, skin preperation - clorexidine gluconate solution- 4% , povidine iodine solution 10% 500 ml., povidine iodine solution 7.5% 500 ml., clorexidine gluconate + ethanol solution. 500 ml., sample container (small), sample container (medium), sample container (large), linear stappler 60 mm 4.8 mm applicator & reload , adult membrane oxygenator with integrated arterial filter. specification - phosphorylcholine coated, fda & ce approved, maximum blood flow rate - 6 litre, membrane surface area - 1.4 m2, static priming volume < 290 ml., should have holders, ce approved, venous filter hold up volume < 25 ml., should have in-built wide-bore re-circulation line., hemo concentrator -pediatric. specification- circuit and bag required, surface area- 0.25 m2, max. blood flow rate- 100 ml/ mt., hemo concentrator membrane - polyethersulfone , ce approved, should have holders, priming volume- 30 ml, max. tmp- 500 mmhg, blood cardioplegea delivery system 14 delnido. specification- max. blood flow rate - 2500 ml/mt., tubing should be high medical grade quality with pressure isolator domes consisting of membrane materials, colour coded lines with pinch clamps, transparent blood path for visibility, integrated bubble trap, should have holders, static priming volume- < / = 30 ml., pressure drop @ 300 ml/mt must be < / = to 5 mmhg., ce approved., heart tissue stabilizer, specification- stabilizer arm should drop 90 degree into the chest cavity for reaching distal vessels, should provide 180 degree swivel movement , should be low profile resulting in increased visibility and surgical field, foot should be mounted on the arm in tri - slot socket for accessing challenging vessels with “toes up” and “toes down” positioning, the foot should have provision for mounting blower mister, should have provision to secure vacuum tubing for hassle free operation, stabilizer must be supplied with disposable access rail and a canister., intra aortic balloon catheter. specification- iab catheter should be of 7.5 fr catheter adult with displacement volume of 30cc & 40 cc. , balloon membrane should be a proprietary membrane & wire-reinforced, it should be more abrasion resistant and have good fatigue resistance, should immediate inflate at start-up without manual filling of the catheter, it should be compatible with datascope, it should have exact 7.5 fr size sheath and dilator set., it should have 0.025” 3mm j ptfe stainless steel guide wire, it should have co-lumen design for faster gas shuttling, it should be approved by us fda / ce approval., percutaneous insertion kit. specification- separate percutaneous insertion kit specifically designed for percutaneous access, should contain 0.038” x 150 cm j tip guide wire advancer, should contain all necessary components including 18 g needle, scalpel & 10 cc syringe, should contain multistep dilators 10/12 fr, 12/14 fr,14/16 fr,16/18 fr., should have option of additional dilator size 18/20 fr, 20/22 fr, 22/24 fr available separately., ptfe graft straight 3 mm (diameter) x 10 cm (length)., bovine pericardial patch 5 x 10 (fda approved), tissue pericardial patch (filamentous knitted polyester fabric) 4” x 4 “., ptfe graft straight 3.5 mm (diameter) |
|
|
If you are a new user, then please
register, it's Free and then fill the form below.
If you are registered with us, just fill the form below, we will get back to you
shortly.
|
All fileds marked with '*' are compulsary.
|
|
|